Abstract
We propose a simplified method for performing an FROC observer study by using regions of interest (ROIs) of CDMAM phantom images as case sample images. This new method would help researchers to plan and perform FROC observer studies in shorter time, with smaller errors and reduced complexity. As examples of experimental procedure, the digital images obtained by a direct-conversion flat-panel detector (FPD) system in three imaging conditions with different levels of patient dose were used to compare the diagnostic accuracies for low-contrast signal detection. There was a high correlation between the average figure of merit (FOM) obtained by our proposed method and inverse image quality figure (inv. IQF) calculated by CDMAM Analyser 1.55 in each dose level (r = 0.98).
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Similar content being viewed by others
References
Bijkerk, K.R., Thijssen, M.A.O., Arnoldussen, T.H.J.M.: Modification of the CDMAM contrast-detail phantom for image quality of Full Field Digital Mammography systems. In: Yaffe, M. (ed.) Proceedings of IWDM 2000, pp. 633–640. Medical Physics Publishing, Madison (2000)
Karssemeijer, N., Thijssen, M.A.O.: Determination of contrast-detail curves of mammography systems by automated image analysis. In: Proceedings of the 3rd International Workshop on Digital Mammography 1996, pp. 155–160 (1996)
Veldkamp, W.J., Thijssen, M.A., Karssemeijer, N.: The value of scatter removal by a grid in full field digital mammography. Med. Phys. 30, 1712–1718 (2003)
Visser, R., Karssemeijer, N.: CDCOM Manual: software for automated readout of CDMAM 3.4 images. (note: CDCOM software, manual and sample images are posted at http://www.euref.org)
Young, K.C., Cook, J.J.H., Oduko, J.M., Bosmans, H.: Comparison of software and human observers in reading images of the CDMAM test object to assess digital mammography systems. In: Flynn, M.J., Hsieh, J. (eds.) Proceedings of SPIE Medical Imaging 2006, vol. 614206, pp. 1–13 (2006)
Young, K.C., Alsager, A., Oduko, J.M., Bosmans, H., Verbrugge, B., Geerste, T., et al.: Evaluation of software for reading images of the CDMAM test object to assess digital mammography systems. In: Proceedings of SPIE Medical Imaging 2008, vol. 69131C, pp. 1–10 (2008)
Figl, M., Hoffmann, R., Kaar, M., Semturs, F., Brasik, N., Birkfellner, W., et al.: Factors for conversion between human and automatic read-outs of CDMAM images. Med. Phys. 38, 5090–5093 (2011)
Delakis, I., Wise, R., Morris, L., Kulama, E.: Performance evaluation of contrast-detail in full field digital mammography systems using ideal (Hotelling) observer vs. conventional automated analysis of CDMAM images for quality control of contrast-detail characteristics. Phys. Med. 31, 741–746 (2015)
Chakraborty, D.P., Berbaum, K.S.: Observer studies involving detection and localization: modeling, analysis, and validation. Med. Phys. 31, 2313–2330 (2004)
European Commission (EC): 2006 European Guidelines for Quality Assurance in Breast Cancer Screening and Diagnosis, 4th edn. Office for Official Publications of the European Communities, Luxembourg (2006)
Shiraishi, J., Fukuoka, D., Hara, T., Abe, H.: Basic concepts and development of an all-purpose computer interface for ROC/FROC observer study. Radiol. Phys. Technol. 6(1), 35–41 (2013)
Oberhofer, N., Paruccini, N., Moroder, E.: Image quality assessment and equipment optimisation with automated phantom evaluation in Full Field Digital Mammography (FFDM). In: Krupinski, E.A. (ed.) IWDM 2008. LNCS, vol. 5116, pp. 235–242. Springer, Heidelberg (2008)
Acknowledgments
The authors are grateful to the staff in the department of Radiology, Shizuoka Cancer Center. This work was supported by JSPS KAKENHI (Grant-in-Aid for Scientific Research) Grant Number 15K09898, and Pfizer Health Research Foundation.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2016 Springer International Publishing Switzerland
About this paper
Cite this paper
Tanaka, R., Akita, F., Fukuoka, D., Bamba, Y., Shiraishi, J. (2016). Simplified Method for FROC Observer Study to Evaluate the Diagnostic Accuracy of a Digital Breast Imaging System by Using a CDMAM Phantom. In: Tingberg, A., Lång, K., Timberg, P. (eds) Breast Imaging. IWDM 2016. Lecture Notes in Computer Science(), vol 9699. Springer, Cham. https://doi.org/10.1007/978-3-319-41546-8_11
Download citation
DOI: https://doi.org/10.1007/978-3-319-41546-8_11
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-319-41545-1
Online ISBN: 978-3-319-41546-8
eBook Packages: Computer ScienceComputer Science (R0)