iBet uBet web content aggregator. Adding the entire web to your favor.
iBet uBet web content aggregator. Adding the entire web to your favor.



Link to original content: https://pubmed.ncbi.nlm.nih.gov/16376750/
Two-dimensional strain--a Doppler-independent ultrasound method for quantitation of regional deformation: validation in vitro and in vivo - PubMed Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2005 Dec;18(12):1247-53.
doi: 10.1016/j.echo.2005.03.024.

Two-dimensional strain--a Doppler-independent ultrasound method for quantitation of regional deformation: validation in vitro and in vivo

Affiliations

Two-dimensional strain--a Doppler-independent ultrasound method for quantitation of regional deformation: validation in vitro and in vivo

Josef Korinek et al. J Am Soc Echocardiogr. 2005 Dec.

Abstract

Background: A new 2-dimensional strain echocardiography (2DSE) method has been introduced that measures myocardial deformations by tracking localized acoustic markers. We compared strains measured in vitro and in vivo by 2DSE with those obtained by sonomicrometry.

Methods: For the in vitro study, a tissue-mimicking gelatin block was cyclically compressed and longitudinal strains obtained by 2DSE and sonomicrometry crystals. For the in vivo study, arrays of crystals were implanted into the apical anteroseptal (test region) and midposterior (control region) in 16 open-chest pigs and strains measured by 2DSE and crystals at baseline and after acute ischemia.

Results: In vitro, pooled data demonstrated good correlation (r = 0.99, P < .0001) and close agreement (bias +/- 2SD = 0.7 +/- 2.2%) of 2DSE and sonomicrometry. For a combination of low testing strains (5.4%) and strain rates (0.8 and 1.2 Hz), 2DSE overestimated strains by sonomicrometry. In vivo, linear regression analysis of pooled measurements demonstrated again a good correlation (r = 0.94, P < .0001) and agreement (1.1 +/- 7.5%) of 2DSE with sonomicrometry with a trend toward lower absolute values of strains by 2DSE.

Conclusion: The 2DSE demonstrated good overall correlation and agreement with sonomicrometry for the tested in vitro and in vivo values. Some caution with 2DSE measurements is needed for combinations of low strains and strain rates.

PubMed Disclaimer

Similar articles

Cited by

Publication types

MeSH terms

LinkOut - more resources