1.Introduction
Structural health monitoring (SHM) technology is perceived as a revolutionary method of determining the integrity of structures, involving the use of multi-disciplinary fields including sensors, materials, signal processing, system integration, and signal interpretation [
1,
2,
3]. Among several types of sensors that can be used for SHM, piezoceramic lead-zirconate-titanate (PZT) sensors have big potential for being widely used because they can be used for both active and passive monitoring. In active model, guided wave theory and electromechanical impedance theory are often used [
4,
5,
6,
7,
8,
9]. Different from conventional ultrasonic technique, the PZT sensors for SHM are permanently bonded on their host structure. Because of small additional weight and high sensitivity to small damage, PZT sensors with thin thickness, which show d31-type piezoelectric effect, are often used in the SHM application for aircraft structures [
10,
11].
The reliability of PZT sensor network for SHM must be entirely guaranteed through the life of host structures. However, the environmental features, such as mechanical loading, temperature, and humidity, can significantly degrade the performance of PZT sensors due to the nature of the PZT material. In particular, PZT sensors can only theoretically survive low tensile strain of 1100 με, which is usually much lower than the strain level of aircraft structures. Some studies were conducted to investigate the durability and survivability of PZT sensors, and different results were obtained when the PZT sensors were exposed to various experimental conditions. For example, one showed that PZT remained operational up to at least 3000 με and failed beyond 6000 με during high-strain tests [
12], but another study showed that the amplitude of the guided wave received by a PZT sensor remained unchanged when the applied strain was lessr than the PZT elongation value of about 1100 με, whereas degradation occurred when the strain exceeded it [
13]. These different results could be caused from the effect of adhesive used to bond the PZT sensor.
Typically, the PZT sensor network used for SHM is permanently bonded with adhesive to the host structure. The adhesive forms an interfacial layer of finite thickness between the piezoelectric element and host structure, and provides the necessary mechanical coupling needed to transfer the forces and strains between the piezoelectric element and the host structure [
12]. The effect of adhesive thickness and its modulus on the performance of adhesively bonded PZT sensors for the purpose of monitoring structural health has been investigated experimentally [
14]. The experimental results revealed that an increase in adhesive thickness alters the electromechanical impedance and the resonant frequency of the PZT sensor as well as the amplitude of the sensor signal. When the modulus is within a certain range, the modulus of the adhesive slightly affects the impedance of the PZT sensor and the amplitude of lower frequency sensor signals, while at high frequency, the impedance response and sensor signal are more sensitive to the modulus of the adhesive. The influence of the adhesive layer on the electromechanical impedance of PZT sensor used has been studied by a few researchers [
15,
16,
17]. Similarly, for guided wave applications, assessment and selection of five types of adhesive were experimentally investigated by Mustapha and Ye [
18]. A hybrid spectral element method was adopted to analyze the influence of adhesive thickness and stiffness, and PZT diameter and thickness on the guided wave generation and reception [
19]. The effect of adhesive, the tone burst, the plate thickness and the transducer thickness on the time reversibility of Lamb waves was also investigated by Agrahari et al [
20]. In addition, a compensation method of the degradation of the adhesive layer for damage detection in SHM was proposed by Mulligan [
21].
Even though many simulation and experimental works have been conducted to investigate the effect of adhesive on the functions of PZT sensors, there is little work performed to study the effect of adhesives on strain transfer from the host structure to the PZT, which would provide a strategy to significantly increase the high tensile strain-bearing ability of PZT sensors to ensure the durability and reliability of SHM systems in real world applications. A preliminary experimental study showed that the high-strain survivability ability of PZT can be enhanced by using different the adhesive material [
22]. In this paper, a further study containing analytical, finite element and experimental solution was conducted to give a systematic understanding about how to increase the high tensile strain bearing ability of PZT. A theoretical model of strain transfer through the adhesive from the host structure to the PZT was first proposed. Then finite element simulation, as well as analytical solution, were conducted to analyze the effect of the adhesive parameters on the strain transfer, which would be used to select a suitable adhesive to reduce the strain of the PZT. Experimental research was finally conducted to validate the analytical and finite element results, which reveal that reducing the shear modulus and enhancing the thickness of the adhesive can decrease the strain transfer from the host structure to the PZT because of the shear lag effect.
2. Theoretical Model of Strain Transfer
For a PZT plate bonded on a host structure shown in
Figure 1, there are three basic components, i.e., PZT, adhesive layer and host structure. The strain of the host structure is transferred to the PZT by the adhesive layer.
The problem of bonding between PZT sensor and host structure is three-dimensional problem. However, this three-dimensional problem is very difficult to carry out accurate mathematical analysis. Through some reasonable simplification, the problem can be simplified to one-dimension problem, and only the stress and strain of the whole structure in the direction of tension are considered since the maximum strain direction on the PZT sensor is basically the same as the tensile direction.
Using the theoretical uniform strain model proposed by Crawley [
23,
24,
25] as the basis, the model of strain transfer between the PZT and the host structure can be obtained based on some assumptions as follows:
- (1)
The adhesive transfers shear stress between the PZT and the host structure;
- (2)
The PZT is uniformly extended;
- (3)
Extension strain is loaded at two ends of the host structure, while two ends of PZT are free.
Considering a micro element of the host structure bonded with the PZT through the adhesive, it is loaded as shown in
Figure 2. The equilibrium equations of PZT and the host structure can be written as:
where
hp and
hb are the thickness of the PZT and the host structure, respectively. Parameter
depends on the stress and strain distributions of the host structure along the thickness direction. At the low frequency range,
if the host structure is purely extended.
when the host structure is purely bended.
for the axial-bending interaction status.
The strain of the PZT, the host structure and the adhesive can be derived as:
where
ha is the adhesive thickness.
The stress of the PZT, the host structure and the adhesive can be obtained as:
where
,
are elastic modulus of the PZT and the host structure, respectively, and
is shear modulus of the adhesive. Substituting Equations (2) and (3) into Equation (1), yields:
The following Equations can also be obtained as:
where
denotes shear lag parameter, and
.
Equation (5a,b) are decoupled equations, but
and
are related as shown in Equation (4).
and
can be obtained by solving Equation (5a,b):
where the coordinate origin of
x-axis is the core of the PZT, and the positive direction of
x-axis is right along the PZT radius. Through the third assumption, if the length of PZT is 2
l, the boundary condition can be written as:
Substituting Equation (7a,b) into Equation (6a,b), it yields:
The strain of the PZT, the adhesive and the host structure can be expressed as:
where
is the strain of the host structure,
represents the strain transfer coefficient from the host structure to the PZT:
By analyzing the strain transmission among the host structure, adhesive and PZT sensor, the expression of strain transfer efficiency is obtained. Then specific parameters can be brought into the quantitative analysis for the cases of strain transfer.
4. The Effect of PZT Configuration on Strain Transfer Coefficient
Through the strain distribution of PZT disk shown in
Figure 5, it is clear that the closer the location is to the center of PZT, the larger the strain is. It is feasible to alternate the material at the center of PZT as another material with good elongation to increase the survivability of PZT at high strain area. For the case in
Section 3.1, consider to alter the center district of PZT with diameter 3 mm as another material. As shown in
Figure 5 and
Figure 11a, when material of the PZT center is altered as another material, with similar elastic modulus but better elongation property, the strain distribution after material alternation is similar as that before, and the largest strain value is close to each other.
When the elastic modulus of the altered material at the PZT center ranges from 0.5 to 1.5 times in step of 0.1 times large than the elastic modulus of PZT, it can be concluded from
Figure 11c that the strain transfer coefficient enhances when the elastic modulus ration keeps away from one. It is because when the gap between elastic modulus of two materials becomes bigger, a worse and worse deformation compatibility occurs so that the strain of the PZT ring becomes larger. When the elastic modulus of central material approaches 0, i.e., the PZT ring has an empty center, the strain transfer coefficient is largest. It is clear that a material, with a good elongation and a similar elastic modulus, to alter the PZT center is preferred to reduce the strain transfer from the host structure.
5. Experimental Verification
An experiment was conducted to verify the correctness of the above theoretical model and finite element analysis. The PZTs were bonded on the specimen using adhesive with different thickness and shear modulus. Since electromechanical impedance method is one of the most common SHM techniques for damage detection by using PZT sensors [
7,
8,
9,
14,
15,
16,
17], the impedance of PZT was employed to assess whether the PZT is failure or not due to the increase of the static load.
The PZTs used in the experiment are APC851 with a diameter of 6.35 mm and thickness of 0.25 mm. An impedance analyzer WK6500 developed by Wayner Kerr Electronics Company in London, UK was utilized to acquire the impedance of a PZT sensor bonded on the surface of an aluminum specimen by Hysol EA 9395 or Hysol EA 9396 developed by Henkel Adhesive Technologies in Westlake, OH, USA, as shown in
Figure 12. A digital electro-hydraulic-servo test machine was used to applied tensile load on the aluminum specimen. Material characteristics of the adhesives are shown in
Table 1.
When Hysol EA 9395 with thickness of 25 μm was adopted as the adhesive to bond the PZT on the aluminum specimen, the impedances of PZT under different strain conditions of the aluminum plate, from 0 to 4000 με in steps of 500 με, were acquired, as shown in
Figure 13a. When the strain of the aluminum plate is larger than 2000 με, the impedance of the PZT has been greatly changed among the working frequency range of guided wave, which is similar to Qing’s viewpoint that when the strain on the PZT exceeds the elongation, the PZT failure occurs [
14]. When the thickness of Hysol EA 9395 was 125 μm, the impedance of the PZT is shown in
Figure 13b. It can be seen that there is only a slight change among the PZT impedances under different strain conditions up to 4000 με.
Based on
Figure 7, it can be calculated that the strain transfer coefficient is just above 0.5 when the thickness of adhesive is 25 μm, while the strain transfer coefficient reduces to about 0.25 when the thickness of adhesive increases to 125 μm. Therefore, using Hysol EA 9395 with thickness of 25 μm to bond PZT, the largest strain in the PZT is above 1000 με, which is close to the elongation of PZT material, when the strain of host structure is more than 2000 με. Using Hysol EA 9395 with thickness of 125 μm to bond PZT, the largest strain in the PZT is just around 1000 με when the strain of the host structure reaches 4000 με.
In order to further verify the variation trend, the impedances of PZT under different strain conditions were studied when the adhesive thickness was set as from 25 μm to 125 μm in steps of 25 μm. An impedance difference coefficient (IDC) is introduced to indicate the difference under current strain condition and free strain condition as:
where
and
represent the impedances under current and free strain conditions, respectively.
Figure 14 gives the variation of impedance difference coefficients with the strain when the adhesive has different thickness. It can be concluded from
Figure 14 that as the adhesive thickness increases, the impedance difference coefficients decrease, which may contribute to the decrease of the strain transfer from the host structure to the PZT.
Figure 15 shows the impedances of PZT under different strain conditions when Hysol EA 9396 was used as the adhesive. It can be obviously seen that the large changes caused by the high strain using Hysol EA 9395 do not occur when using Hysol EA 9396, which indicates that the strain transfer coefficient decreases as the shear modulus of the adhesive is reduced. This verifies the simulation results in
Figure 7.
6. Discussion and Conclusions
Due to the material nature, PZT sensors have low reliability when mounted at locations exposed to a large tensile strain. A novel approach to greatly improve the strain survivability of PZT by optimal design of the bonding adhesive has been proposed. A one-dimension theoretical model is proposed and three-dimension finite element model is developed to study the strain transfer from the host structure to the PZT sensor. Although there is a slight value difference of strain transfer coefficients for the geometry difference between the theoretical model and finite element model, the results from both models show very similar variation trends of strain transfer coefficients with the adhesive parameters, and are mutual authenticated. Based on the theoretical model established, finite element method developed and experiments conducted, it is clear that the PZT sensor can work perfectly when it is mounted on the host structure with tensile strain up to 4000 με by using optimal adhesive. This is because the strain transferred to the PZT is still less than 1100 με, which is the maximum tensile strain PZT can bear, even the strain of host structure reaches 4000 με. The following remarks can be made based on the above investigation:
With the increase of the thickness of adhesive layer, the efficiency of strain transfer decreases, the maximum strain transferred from the host structure to the PZT sensor decreases, as well as the high strain area decreases, concentrating to the center of PZT sensor.
With the increase of the shear modulus of the adhesive layer, the efficiency of strain transfer increases. After the shear modulus of adhesive layer increases to a certain value, the efficiency of strain transfer at area with maximum strain will not increase, but the high strain region increases.
With increasing radius/length of the PZT sensor, the efficiency of strain transfer increases, and the high strain area increases.Alternating the material at the center of PZT sensor with another material with good elongation can increase the survivability of PZT in high strain areas.