Abstract
The change in the edema condition is visualized considering the three-dimensional shape. Continuous treatment and observation are indispensable for patients with edema. The measurement and evaluation of the three-dimensional shape of the leg are thus important in evaluating edema of the leg. Such an evaluation can confirm the therapeutic effect and assist in the planning of treatment by confirming the change in local capacity. Additionally, the depth camera of Structure Sensor used this study is feasible for use in home care systems due to its very low cost compared with other depth cameras. We obtain a point cloud of the leg and register shape models. We conducted an experiment to measure legs swathed and not swathed in bandages, with the former representing a leg with edema. In addition, for visualization of the edema condition, the change in shape was color coded according to the change obtained in the proposed analysis of the three-dimensional shape. Our experimental results show that our proposed visualization technique is effective in conveying the change in shape visually and clearly.
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.References
Katherine K, Fleischer A, Yosipovitch G (2008) Lower extremity lymphedema: update: pathophysiology, diagnosis, and treatment guidelines. J Am Acad Dermatol 59(2):324–331
Ogawa Y (2012) Recent advances in medical treatment for lymphedema. Ann Vasc Dis 5(2):139–144
Mayrovitz HN, Sims N, Macdonald J (2000) Assessment of limb volume by manual and automated methods in patients with limb edema or lymphedema. Adv Skin Wound Care 13(6):272–276
Tiwari A, Cheng KS, Button M et al (2003) Differential diagnosis, investigation, and current treatment of lower limb lymphedema. Arch Surg 138(2):152–161
Tan CW, Coutts F, Bulley C (2013) Measurement of lower limb volume: agreement between the vertically oriented perometer and a tape measure method. Physiotherapy 99(3):247–251
Hirai M, Nukumizu Y, Kidokoro H et al (2006) Effect of elastic compression stockings on oedema prevention in healthy controls evaluated by a three-dimensional measurement system. Skin Res Technol 12(1):32–35
Cau N, Corna S, Aspesi V et al (2016) Circumferential versus hand-held laser scanner method for the evaluation of lower limb volumes in normal-weight and obese subjects. J Nov Physiother 6(303):2
Kiyomitsu K, Kakinuma A, Takahashi H et al (2017) Volume measurement of the leg by using Kinect Fusion for quantitative evaluation of edemas. Bull Soc Photogr Imaging Jpn 27(1):7–12
Kinect for Windows Sensor (2018) https://docs.microsoft.com/en-us/previous-versions/microsoft-robotics/hh438998(v%3dmsdn.10). Accessed 3 Jun 2019
Structure Sensor (2019) 3D scanning, augmented reality, and more for mobile devices. http://structure.io. Accessed 3 Jun 2019
Skanect 3D Scanning Software By Occipital (2019) The easiest way to 3D scan with the structure sensor and Kinect-like 3D sensors. https://skanect.occipital.com. Accessed 3 Jun 2019
Cignoni P, Callieri M, Corsini M et al (2008) MeshLab: an open-source mesh processing tool. In: Eurographics Italian chapter conference, pp 129–136. https://doi.org/10.2312/LocalChapterEvents/ItalChap/ItalianChapConf2008/129-136
Yang J, Li H et al (2016) Go-ICP: a globally optimal solution to 3D ICP point-set registration. IEEE Trans Pattern Anal Mach Intell 38(11):2241–2254
Lawler EL, Wood DE (1966) Branch-and-bound methods: a survey. Oper Res 14:699–719
Möller T, Trumbore B (1997) Fast, minimum storage ray–triangle intersection. J Graphics Tools 2:21–28
Acknowledgements
We thank Glenn Pennycook, MSc, from Edanz Group (www.edanzediting.com/ac) for editing a draft of this manuscript.
Author information
Authors and Affiliations
Corresponding author
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
About this article
Cite this article
Masui, K., Kiyomitsu, K., Ogawa-Ochiai, K. et al. Technology for visualizing the local change in shape of edema using a depth camera. Artif Life Robotics 24, 480–486 (2019). https://doi.org/10.1007/s10015-019-00541-1
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10015-019-00541-1