{"id":"https://openalex.org/W2275321574","doi":"https://doi.org/10.1109/iecon.2015.7392155","title":"Flexible power distribution unit \u2014 A novel power electronic transformer development and demonstration for distribution system","display_name":"Flexible power distribution unit \u2014 A novel power electronic transformer development and demonstration for distribution system","publication_year":2015,"publication_date":"2015-11-01","ids":{"openalex":"https://openalex.org/W2275321574","doi":"https://doi.org/10.1109/iecon.2015.7392155","mag":"2275321574"},"language":"en","primary_location":{"is_oa":false,"landing_page_url":"https://doi.org/10.1109/iecon.2015.7392155","pdf_url":null,"source":null,"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false},"type":"article","type_crossref":"proceedings-article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5102435956","display_name":"Qing Duan","orcid":null},"institutions":[{"id":"https://openalex.org/I153473198","display_name":"North China Electric Power University","ror":"https://ror.org/04qr5t414","country_code":"CN","type":"education","lineage":["https://openalex.org/I153473198"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Qing Duan","raw_affiliation_strings":["China Electric Power Research Institute & Beijing, Key Laboratory of Distribution Transformer Energy-saving Technology, Beijing, China"],"affiliations":[{"raw_affiliation_string":"China Electric Power Research Institute & Beijing, Key Laboratory of Distribution Transformer Energy-saving Technology, Beijing, China","institution_ids":["https://openalex.org/I153473198"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100420019","display_name":"Jianhua Wang","orcid":"https://orcid.org/0000-0001-5185-4506"},"institutions":[{"id":"https://openalex.org/I76569877","display_name":"Southeast University","ror":"https://ror.org/04ct4d772","country_code":"CN","type":"education","lineage":["https://openalex.org/I76569877"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Jianhua Wang","raw_affiliation_strings":["Jiangsu Provincial Key Laboratory of Smart Grid Technology & Equipment, Southeast University, Nanjing, China"],"affiliations":[{"raw_affiliation_string":"Jiangsu Provincial Key Laboratory of Smart Grid Technology & Equipment, Southeast University, Nanjing, China","institution_ids":["https://openalex.org/I76569877"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5101531526","display_name":"Chunyan Ma","orcid":"https://orcid.org/0000-0003-4453-9334"},"institutions":[{"id":"https://openalex.org/I153473198","display_name":"North China Electric Power University","ror":"https://ror.org/04qr5t414","country_code":"CN","type":"education","lineage":["https://openalex.org/I153473198"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Chunyan Ma","raw_affiliation_strings":["China Electric Power Research Institute & Beijing, Key Laboratory of Distribution Transformer Energy-saving Technology, Beijing, China"],"affiliations":[{"raw_affiliation_string":"China Electric Power Research Institute & Beijing, Key Laboratory of Distribution Transformer Energy-saving Technology, Beijing, China","institution_ids":["https://openalex.org/I153473198"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5086872912","display_name":"Binshi Gu","orcid":null},"institutions":[{"id":"https://openalex.org/I76569877","display_name":"Southeast University","ror":"https://ror.org/04ct4d772","country_code":"CN","type":"education","lineage":["https://openalex.org/I76569877"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Binshi Gu","raw_affiliation_strings":["Jiangsu Provincial Key Laboratory of Smart Grid Technology & Equipment, Southeast University, Nanjing, China"],"affiliations":[{"raw_affiliation_string":"Jiangsu Provincial Key Laboratory of Smart Grid Technology & Equipment, Southeast University, Nanjing, China","institution_ids":["https://openalex.org/I76569877"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5010163563","display_name":"Baojian Ji","orcid":"https://orcid.org/0000-0002-9594-800X"},"institutions":[{"id":"https://openalex.org/I134687103","display_name":"Nanjing Tech University","ror":"https://ror.org/03sd35x91","country_code":"CN","type":"education","lineage":["https://openalex.org/I134687103"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Baojian Ji","raw_affiliation_strings":["College of Automation and Electrical Engineering, Nanjing Tech University, Nanjing, China"],"affiliations":[{"raw_affiliation_string":"College of Automation and Electrical Engineering, Nanjing Tech University, Nanjing, China","institution_ids":["https://openalex.org/I134687103"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5005689727","display_name":"Peng Qiu","orcid":"https://orcid.org/0000-0003-0482-2899"},"institutions":[{"id":"https://openalex.org/I134687103","display_name":"Nanjing Tech University","ror":"https://ror.org/03sd35x91","country_code":"CN","type":"education","lineage":["https://openalex.org/I134687103"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Peng Qiu","raw_affiliation_strings":["College of Automation and Electrical Engineering, Nanjing Tech University, Nanjing, China"],"affiliations":[{"raw_affiliation_string":"College of Automation and Electrical Engineering, Nanjing Tech University, Nanjing, China","institution_ids":["https://openalex.org/I134687103"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5101040971","display_name":"Jun You","orcid":null},"institutions":[{"id":"https://openalex.org/I76569877","display_name":"Southeast University","ror":"https://ror.org/04ct4d772","country_code":"CN","type":"education","lineage":["https://openalex.org/I76569877"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Jun You","raw_affiliation_strings":["Jiangsu Provincial Key Laboratory of Smart Grid Technology & Equipment, Southeast University, Nanjing, China"],"affiliations":[{"raw_affiliation_string":"Jiangsu Provincial Key Laboratory of Smart Grid Technology & Equipment, Southeast University, Nanjing, China","institution_ids":["https://openalex.org/I76569877"]}]}],"institution_assertions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":1.311,"has_fulltext":true,"fulltext_origin":"ngrams","cited_by_count":10,"citation_normalized_percentile":{"value":0.748624,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":86,"max":87},"biblio":{"volume":null,"issue":null,"first_page":"000534","last_page":"000537"},"is_retracted":false,"is_paratext":false,"primary_topic":{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.9998,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.9998,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10361","display_name":"Silicon Carbide Semiconductor Technologies","score":0.9991,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11444","display_name":"Electromagnetic Compatibility and Noise Suppression","score":0.9969,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/power-electronics","display_name":"Power Electronics","score":0.6853194}],"concepts":[{"id":"https://openalex.org/C178911571","wikidata":"https://www.wikidata.org/wiki/Q593143","display_name":"Power electronics","level":3,"score":0.6853194},{"id":"https://openalex.org/C117323899","wikidata":"https://www.wikidata.org/wiki/Q1907989","display_name":"Distribution transformer","level":4,"score":0.64231855},{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.5296043},{"id":"https://openalex.org/C138331895","wikidata":"https://www.wikidata.org/wiki/Q11650","display_name":"Electronics","level":2,"score":0.5219473},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.52134216},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.49999738},{"id":"https://openalex.org/C151799858","wikidata":"https://www.wikidata.org/wiki/Q587008","display_name":"Switched-mode power supply","level":3,"score":0.48378488},{"id":"https://openalex.org/C180850520","wikidata":"https://www.wikidata.org/wiki/Q2166404","display_name":"Isolation transformer","level":4,"score":0.4587671},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.41823438},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.34317768},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.11479792}],"mesh":[],"locations_count":1,"locations":[{"is_oa":false,"landing_page_url":"https://doi.org/10.1109/iecon.2015.7392155","pdf_url":null,"source":null,"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.89,"display_name":"Affordable and clean energy"}],"grants":[],"datasets":[],"versions":[],"referenced_works_count":8,"referenced_works":["https://openalex.org/W1523836303","https://openalex.org/W1880270725","https://openalex.org/W1978262178","https://openalex.org/W2065388820","https://openalex.org/W2077711491","https://openalex.org/W2089796964","https://openalex.org/W2356116899","https://openalex.org/W2373170816"],"related_works":["https://openalex.org/W3194652096","https://openalex.org/W3017739981","https://openalex.org/W2766995343","https://openalex.org/W2492373545","https://openalex.org/W2388178350","https://openalex.org/W2371970260","https://openalex.org/W2358878017","https://openalex.org/W2228554074","https://openalex.org/W2039168322","https://openalex.org/W149558712"],"abstract_inverted_index":{"Power":[0],"electronic":[1],"transformer":[2,40],"(PET)":[3],"is":[4,49,64,74],"an":[5],"emerging":[6],"new":[7],"type":[8],"of":[9,22,32],"power":[10,23,33,38,46],"converter":[11],"in":[12,51,78],"recent":[13],"years.":[14],"It":[15],"has":[16],"not":[17],"only":[18],"the":[19,29,55,60,85],"basic":[20],"functions":[21,31],"transformation":[24],"and":[25,54,62,76,88],"isolation,":[26],"but":[27],"also":[28],"extra":[30],"quality":[34],"control.":[35],"A":[36],"novel":[37],"electronics":[39],"for":[41],"distribution":[42,47],"system":[43],"named":[44],"flexible":[45],"unit":[48],"proposed":[50,86],"this":[52],"paper,":[53],"energy":[56],"exchange":[57],"mechanism":[58],"between":[59],"network":[61],"load":[63],"revealed.":[65],"Finally,":[66],"a":[67],"100kW":[68],"600Vac/220Vac/110Vdc":[69],"medium":[70],"frequency":[71],"isolated":[72],"prototype":[73],"developed":[75],"demonstrated":[77],"laboratory.":[79],"The":[80],"experimental":[81],"results":[82],"show":[83],"that":[84],"structure":[87],"control":[89],"strategy":[90],"are":[91],"feasible.":[92]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W2275321574","counts_by_year":[{"year":2023,"cited_by_count":2},{"year":2021,"cited_by_count":1},{"year":2020,"cited_by_count":3},{"year":2017,"cited_by_count":3},{"year":2015,"cited_by_count":1}],"updated_date":"2024-12-12T18:45:28.569640","created_date":"2016-06-24"}