iBet uBet web content aggregator. Adding the entire web to your favor.
iBet uBet web content aggregator. Adding the entire web to your favor.



Link to original content: https://api.crossref.org/works/10.1002/IMA.22440
{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,5,28]],"date-time":"2024-05-28T02:10:08Z","timestamp":1716862208835},"reference-count":39,"publisher":"Wiley","issue":"4","license":[{"start":{"date-parts":[[2020,5,21]],"date-time":"2020-05-21T00:00:00Z","timestamp":1590019200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Int J Imaging Syst Tech"],"published-print":{"date-parts":[[2020,12]]},"abstract":"Abstract<\/jats:title>Ultrasound imaging is an important modality used in medical imaging. One of the significant stages in the ultrasound imaging is the beamforming process. This article proposes a new technique for reducing the overall computational time of adaptive linear ultrasound imaging. The method uses the discrete cosine transform\u2010based reconstruction for missing data imputation. The novelty of the paper is that we do not need to beam\u2010form the total scan lines, so the time of image construction can be saved significantly. In other words, a fraction of the total scan lines is selected for beamforming and the others are assumed to have values as Not\u2010a\u2010Number (NaN). The proposed reconstruction technique tries to assign appropriate values to the NaN ones. We applied the proposed method to the simulated and experimental radio frequency (RF) datasets for resolution and contrast evaluation. Results showed that the proposed technique is near to the minimum variance (MV) method in terms of resolution and contrast, and has less computational time for image formation compared to the MV. As some quantitative examples in some experiments we have formed only 50% and 33% of the total lines and reconstructed the rest, then we have been able to increase the frame rate twice and three times, respectively, which can be very useful in many applications, especially in echocardiography imaging. In addition, since the execution time of the reconstruction algorithm is not very significant, we were also able to increase the speed by two and three times while achieving an error of less than 10% compared to the case of using all image lines.<\/jats:p>","DOI":"10.1002\/ima.22440","type":"journal-article","created":{"date-parts":[[2020,5,21]],"date-time":"2020-05-21T22:46:01Z","timestamp":1590101161000},"page":"1080-1094","update-policy":"http:\/\/dx.doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":12,"title":["A fast and high frame rate adaptive beamforming using DCT<\/scp>\u2010based RF<\/scp>\u2010line recovery in line\u2010by\u2010line ultrasound imaging"],"prefix":"10.1002","volume":"30","author":[{"ORCID":"http:\/\/orcid.org\/0000-0002-4184-9436","authenticated-orcid":false,"given":"Sajjad","family":"Afrakhteh","sequence":"first","affiliation":[{"name":"School of Electrical Engineering, Biomedical Engineering Department Iran University of Science and Technology (IUST) Tehran Iran"}]},{"ORCID":"http:\/\/orcid.org\/0000-0002-1698-5284","authenticated-orcid":false,"given":"Hamid","family":"Behnam","sequence":"additional","affiliation":[{"name":"School of Electrical Engineering, Biomedical Engineering Department Iran University of Science and Technology (IUST) Tehran Iran"}]}],"member":"311","published-online":{"date-parts":[[2020,5,21]]},"reference":[{"key":"e_1_2_6_2_1","doi-asserted-by":"publisher","DOI":"10.1109\/53.665"},{"key":"e_1_2_6_3_1","doi-asserted-by":"publisher","DOI":"10.1109\/TSP.2005.845436"},{"key":"e_1_2_6_4_1","unstructured":"MannJA WalkerWF. A constrained adaptive beamformer for medical ultrasound: Initial results. Paper presented at: Proceedings of the 2002 IEEE Ultrasonics Symposium.2002. p.1807\u20131810."},{"key":"e_1_2_6_5_1","doi-asserted-by":"publisher","DOI":"10.1109\/PROC.1969.7278"},{"key":"e_1_2_6_6_1","unstructured":"SynnevagJF AustengA HolmS. Minimum variance adaptive beamforming applied to medical ultrasound imaging. Paper presented at: Proceedings of the IEEE Ultrasonics Symposium.2005. p. 1199\u20131202."},{"key":"e_1_2_6_7_1","doi-asserted-by":"publisher","DOI":"10.1109\/TUFFC.2011.1880"},{"key":"e_1_2_6_8_1","doi-asserted-by":"publisher","DOI":"10.1109\/TUFFC.2009.1268"},{"key":"e_1_2_6_9_1","doi-asserted-by":"publisher","DOI":"10.1109\/78.482097"},{"key":"e_1_2_6_10_1","doi-asserted-by":"publisher","DOI":"10.1109\/TUFFC.2010.1706"},{"key":"e_1_2_6_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.sigpro.2012.10.021"},{"key":"e_1_2_6_12_1","doi-asserted-by":"publisher","DOI":"10.1109\/TMI.2012.2208469"},{"key":"e_1_2_6_13_1","doi-asserted-by":"publisher","DOI":"10.1109\/TUFFC.2017.2710102"},{"key":"e_1_2_6_14_1","doi-asserted-by":"crossref","unstructured":"BaiC JiM WanM. Fast adaptive beamforming combined with multiple apodization in ultrasound plane wave imaging. Paper presented at: 2016 IEEE International Ultrasonics Symposium (IUS).2016. Available from: https:\/\/doi.org\/10.1109\/ULTSYM.2016.7728904.","DOI":"10.1109\/ULTSYM.2016.7728904"},{"key":"e_1_2_6_15_1","doi-asserted-by":"crossref","unstructured":"AchimA BuxtonB TzagkarakisG Tsakalides P. Compressive sensing for ultrasound RF echoes using a\u2010stable distributions. Paper presented at: 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology.2010. p.4304\u20134307.","DOI":"10.1109\/IEMBS.2010.5626210"},{"key":"e_1_2_6_16_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ultras.2012.09.008"},{"key":"e_1_2_6_17_1","doi-asserted-by":"publisher","DOI":"10.1109\/TSP.2012.2200891"},{"key":"e_1_2_6_18_1","doi-asserted-by":"publisher","DOI":"10.1155\/2012\/231317"},{"key":"e_1_2_6_19_1","doi-asserted-by":"crossref","unstructured":"QuinsacC BasarabA GiraultJ\u2010M Kouam\u00e9D. Compressed sensing of ultrasound images: sampling of spatial and frequency domains. Paper presented at: 2010 IEEE Workshop On Signal Processing Systems.2010. p.231\u2013236.","DOI":"10.1109\/SIPS.2010.5624793"},{"key":"e_1_2_6_20_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.bspc.2019.03.003"},{"key":"e_1_2_6_21_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ultras.2019.105979"},{"key":"e_1_2_6_22_1","doi-asserted-by":"publisher","DOI":"10.1109\/TUFFC.2014.2989"},{"key":"e_1_2_6_23_1","doi-asserted-by":"publisher","DOI":"10.1109\/TUFFC.2011.1805"},{"key":"e_1_2_6_24_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ultras.2017.12.012"},{"key":"e_1_2_6_25_1","doi-asserted-by":"publisher","DOI":"10.1109\/TUFFC.2015.2493881"},{"key":"e_1_2_6_26_1","doi-asserted-by":"publisher","DOI":"10.1109\/TMI.2014.2371235"},{"key":"e_1_2_6_27_1","doi-asserted-by":"publisher","DOI":"10.1109\/TSP.2007.911498"},{"key":"e_1_2_6_28_1","doi-asserted-by":"crossref","unstructured":"LiuJ HeQ LuoJ. Compressed sensing for high frame rate high resolution and high contrast ultrasound imaging. Paper presented at: 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) 2015.","DOI":"10.1109\/EMBC.2015.7318668"},{"key":"e_1_2_6_29_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.csda.2009.09.020"},{"key":"e_1_2_6_30_1","volume-title":"Generalized additive models","author":"Hastie T","year":"1990"},{"key":"e_1_2_6_31_1","doi-asserted-by":"publisher","DOI":"10.1214\/ss\/1038425655"},{"key":"e_1_2_6_32_1","doi-asserted-by":"publisher","DOI":"10.1137\/1.9781611970128"},{"key":"e_1_2_6_33_1","doi-asserted-by":"publisher","DOI":"10.1021\/ac034173t"},{"key":"e_1_2_6_34_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.csda.2006.11.038"},{"key":"e_1_2_6_35_1","first-page":"210","article-title":"Eigenvalues of several tridiagonal matrices","volume":"5","author":"Yueh W\u2010C","year":"2005","journal-title":"Appl Math e\u2010Notes"},{"key":"e_1_2_6_36_1","doi-asserted-by":"publisher","DOI":"10.3390\/app9030486"},{"key":"e_1_2_6_37_1","doi-asserted-by":"publisher","DOI":"10.1021\/ac60319a045"},{"key":"e_1_2_6_38_1","doi-asserted-by":"crossref","unstructured":"Rodriguez\u2010MolaresA RindalOMH BernardO NairA BellMAL LiebgottH et al. The ultrasound toolbox. Paper presented at: 2017 IEEE International Ultrasonics Symposium (IUS).2017. p.1\u20134.","DOI":"10.1109\/ULTSYM.2017.8092026"},{"key":"e_1_2_6_39_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ultrasmedbio.2017.05.023"},{"key":"e_1_2_6_40_1","doi-asserted-by":"publisher","DOI":"10.1109\/TIP.2011.2173206"}],"container-title":["International Journal of Imaging Systems and Technology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fima.22440","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/ima.22440","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1002\/ima.22440","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/ima.22440","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,4]],"date-time":"2023-09-04T14:27:08Z","timestamp":1693837628000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/ima.22440"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,5,21]]},"references-count":39,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2020,12]]}},"alternative-id":["10.1002\/ima.22440"],"URL":"https:\/\/doi.org\/10.1002\/ima.22440","archive":["Portico"],"relation":{},"ISSN":["0899-9457","1098-1098"],"issn-type":[{"value":"0899-9457","type":"print"},{"value":"1098-1098","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,5,21]]},"assertion":[{"value":"2020-01-21","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2020-04-26","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2020-05-21","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}