Implantable glucose sensors for diabetes monitoring
- PMID: 16754492
- DOI: 10.1080/13645700410026993
Implantable glucose sensors for diabetes monitoring
Abstract
The development of glucose sensors for clinical use is driven by the aim of blood glucose normalization in diabetic patients, and the detection of blood glucose impairment in nondiabetic subjects submitted to critical conditions. Currently available devices for continuous glucose monitoring are either minimally invasive or partly implantable, and measure subcutaneous interstitial glucose using glucose-oxidase. The signal generated is calibrated against capillary blood glucose to provide estimated blood glucose values. The three certified glucose sensing systems for clinical use: GlucoWatch(R) biographer, CGMS(R) and GlucoDay(R) use different techniques for glucose recovery: reverse iontophoresis, direct subcutaneous implantation and microdialysis, respectively. These devices show sufficient accuracy to identify trends of blood glucose variations, but provide information either with significant delay (GlucoWatch(R)) or retrospectively after computerized analysis of "Holter-style" glucose recordings (CGMS(R), GlucoDay(R)). Only GlucoDay(R) can provide almost online data. Occasional use for short-term assessment of glucose control or educational purposes in diabetic subjects dominates the present clinical use of these devices. Because of the discrepancies between variations of blood and interstitial glucose levels, treatment adaptations from collected sensor data still need further assessment by capillary blood glucose measurements, while the limited biocompatibility of these systems allows only short-term recordings for a few days at most. Subcutaneous and intravenous, fully implantable, sensor models are currently under development and evaluated in clinical trials. Designed for long-term glucose sensing and permanent clinical use, these glucose sensors show promising early results in view of open-loop or closed-loop insulin delivery based upon a sensor signal.
Similar articles
-
Implantable glucose sensors: present status and future developments.Exp Clin Endocrinol Diabetes. 2001;109 Suppl 2:S341-6. doi: 10.1055/s-2001-18593. Exp Clin Endocrinol Diabetes. 2001. PMID: 11460582 Review.
-
Continuous glucose monitoring in interstitial fluid using glucose oxidase-based sensor compared to established blood glucose measurement in rats.Anal Chim Acta. 2007 Jan 2;581(1):7-12. doi: 10.1016/j.aca.2006.08.016. Epub 2006 Aug 18. Anal Chim Acta. 2007. PMID: 17386418
-
[From external to implantable insulin pump, can we close the loop?].Diabetes Metab. 2002 Sep;28(4 Pt 2):2S19-2S25. Diabetes Metab. 2002. PMID: 12442060 French.
-
[Biosensors for continuous glucose and lactate monitoring].Ned Tijdschr Geneeskd. 2003 Jun 21;147(25):1204-8. Ned Tijdschr Geneeskd. 2003. PMID: 12848054 Review. Dutch.
-
Sensor-augmented pump therapy in type 1 diabetes.Curr Opin Endocrinol Diabetes Obes. 2008 Apr;15(2):118-22. doi: 10.1097/MED.0b013e3282f7960b. Curr Opin Endocrinol Diabetes Obes. 2008. PMID: 18316945 Review.
Cited by
-
A Survey on Wireless Wearable Body Area Networks: A Perspective of Technology and Economy.Sensors (Basel). 2022 Oct 11;22(20):7722. doi: 10.3390/s22207722. Sensors (Basel). 2022. PMID: 36298073 Free PMC article. Review.
-
Sensing and Artificial Intelligent Maternal-Infant Health Care Systems: A Review.Sensors (Basel). 2022 Jun 9;22(12):4362. doi: 10.3390/s22124362. Sensors (Basel). 2022. PMID: 35746144 Free PMC article. Review.
-
Non-invasive platform to estimate fasting blood glucose levels from salivary electrochemical parameters.Healthc Technol Lett. 2019 Jul 9;6(4):87-91. doi: 10.1049/htl.2018.5081. eCollection 2019 Aug. Healthc Technol Lett. 2019. PMID: 31531221 Free PMC article.
-
Implantable Sensors for Regenerative Medicine.J Biomech Eng. 2017 Feb 1;139(2):0210091-02100911. doi: 10.1115/1.4035436. J Biomech Eng. 2017. PMID: 27987300 Free PMC article. Review.
-
Mobile-cloud assisted video summarization framework for efficient management of remote sensing data generated by wireless capsule sensors.Sensors (Basel). 2014 Sep 15;14(9):17112-45. doi: 10.3390/s140917112. Sensors (Basel). 2014. PMID: 25225874 Free PMC article.
LinkOut - more resources
Full Text Sources
Other Literature Sources