iBet uBet web content aggregator. Adding the entire web to your favor.
iBet uBet web content aggregator. Adding the entire web to your favor.



Link to original content: http://pubmed.ncbi.nlm.nih.gov/9114385/
Measurement of levels of human immunodeficiency virus type 1 reverse transcriptase (RT) and RT activity-blocking antibody in human serum by a new standardized colorimetric assay - PubMed Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1997 May;35(5):1080-9.
doi: 10.1128/jcm.35.5.1080-1089.1997.

Measurement of levels of human immunodeficiency virus type 1 reverse transcriptase (RT) and RT activity-blocking antibody in human serum by a new standardized colorimetric assay

Affiliations

Measurement of levels of human immunodeficiency virus type 1 reverse transcriptase (RT) and RT activity-blocking antibody in human serum by a new standardized colorimetric assay

R J Awad et al. J Clin Microbiol. 1997 May.

Abstract

Standardization and calibration of a new colorimetric assay for detection of reverse transcriptase (RT) was carried out for optimal detection of RT activity-blocking antibody (RTb-Ab) in serum. A total of 99 of 100 Swedish and 54 of 54 African human immunodeficiency virus type 1 (HIV-1) antibody-positive individuals had RTb-Ab. The one RTb-Ab-negative HIV-1 serum sample from a Swedish individual was obtained early during seroconversion. Five of 615 HIV-1-negative sera from tumor patients, pregnant women, patients undergoing routine viral diagnostics, and blood donors gave false-positive results. In addition, 3 of 126 HIV-1-negative African serum samples and 2 of 91 serum samples selected because of false reactivity in other commercially available HIV antibody assays were positive for RTb-Ab. RT activity and RTb-Ab were measured in sera from newly HIV-1-infected individuals during seroconversion. Peak RT activity was usually detected between days 8 and 13 after the onset of symptoms of primary infection. In addition, HIV-1 RTb-Ab was detected in the same recently infected individuals in most cases within 1 month and in some cases as early as 10 to 12 days after the onset of symptoms. A cross-reactivity study involving HIV-1 and HIV-2 RTb-Abs and their homologous RT showed HIV-1 RTb-Ab to be highly type specific. None of 10 serum samples from HIV-1-infected individuals showed cross-reacting RTb-Ab toward HIV-2 RT, whereas 4 of 10 serum samples from HIV-2-infected patients showed cross-reactivity toward HIV-1 RT; however, the cross-reactivity toward HIV-1 RT was 3,000 times lower than that toward its homologous RT. Future uses for the assay with reference to the recent World Health Organization proposal for other methods instead of Western blotting (immunoblotting) for confirming HIV-1 infection and for methods for the diagnosis of infection as follow-up in vaccine trials are also discussed.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Science. 1986 Mar 14;231(4743):1289-91 - PubMed
    1. Anal Biochem. 1996 Mar 15;235(2):141-52 - PubMed
    1. Nature. 1987 Apr 9-15;326(6113):610-3 - PubMed
    1. J Clin Immunol. 1987 May;7(3):218-24 - PubMed
    1. J Clin Microbiol. 1987 Dec;25(12):2415-7 - PubMed

Publication types