Hospital Environmental Factors That Influence Peripheral Oxygen Saturation Measurements: A Cross-Sectional Study
- PMID: 38727497
- PMCID: PMC11083166
- DOI: 10.3390/healthcare12090940
Hospital Environmental Factors That Influence Peripheral Oxygen Saturation Measurements: A Cross-Sectional Study
Abstract
Pulse oximetry is a non-invasive, cost-effective, and generally reliable instrument measuring pulse rate and peripheral oxygen saturation (SpO2). However, these measurements can be affected by the patient's internal or external factors, including the type of pulse oximeter device (POD). (1) This study's objective was to identify potential environmental factors that may impact the measurements taken by three PODs. (2) Methods: A descriptive-analytical cross-sectional study was designed. The patients' SpO2 levels were measured using a standard monitor and two PODs owned by the professionals. The measurements were taken on the patients' fingers. Concurrently, we evaluated the surrounding environmental conditions, encompassing temperature, humidity, illuminance, and noise. (3) Results: This study involved 288 adult participants in the sample. For each 20-decibel increment in noise, there was a reduction in SpO2 by an average of 1%, whereas for every additional degree of ambient temperature, SpO2 decreased by an average of 2% (4) Conclusions: Significant correlations between SpO2 and age, as well as with noise and ambient temperature, were observed. No significant differences between oxygen saturation and lighting or humidity were observed. This study was prospectively registered with the Clinical Research Ethics Committee of Gran Canaria at the Dr. Negrín University Hospital, with protocol code 2019-247-1, and approved on 24 May 2019.
Keywords: environmental factors; humidity; illuminance; noise; peripheral oximetry; pulse oximeters; skin phototype; temperature.
Conflict of interest statement
The authors declare no conflicts of interest.
Similar articles
-
Comparative Study of Spo2 in all the Fingers of the Hands Measured by Pulse Oximeter.J Assoc Physicians India. 2022 Apr;70(4):11-12. J Assoc Physicians India. 2022. PMID: 35443453
-
Perioperative comparison of the agreement between a portable fingertip pulse oximeter v. a conventional bedside pulse oximeter in adult patients (COMFORT trial).S Afr Med J. 2019 Feb 26;109(3):154-158. doi: 10.7196/SAMJ.2019.v109i3.13633. S Afr Med J. 2019. PMID: 30834870 Clinical Trial.
-
Clinical Outcomes Associated With Overestimation of Oxygen Saturation by Pulse Oximetry in Patients Hospitalized With COVID-19.JAMA Netw Open. 2023 Aug 1;6(8):e2330856. doi: 10.1001/jamanetworkopen.2023.30856. JAMA Netw Open. 2023. PMID: 37615985 Free PMC article.
-
Impacts of Skin Color and Hypoxemia on Noninvasive Assessment of Peripheral Blood Oxygen Saturation: A Scoping Review.Cureus. 2023 Sep 27;15(9):e46078. doi: 10.7759/cureus.46078. eCollection 2023 Sep. Cureus. 2023. PMID: 37900526 Free PMC article. Review.
-
Racial Disparity in Oxygen Saturation Measurements by Pulse Oximetry: Evidence and Implications.Ann Am Thorac Soc. 2022 Dec;19(12):1951-1964. doi: 10.1513/AnnalsATS.202203-270CME. Ann Am Thorac Soc. 2022. PMID: 36166259 Review.
References
-
- Vogelmeier C.F., Criner G.J., Martinez F.J., Anzueto A., Barnes P.J., Bourbeau J., Celli B.R., Chen R., Decramer M., Fabbri L.M., et al. Global strategy for the diagnosis, management, and prevention of chronic obstructive lung disease 2017 report. GOLD executive summary. Am. J. Respir. Crit. Care Med. 2017;195:557–582. doi: 10.1164/rccm.201701-0218PP. - DOI - PubMed
Grants and funding
LinkOut - more resources
Full Text Sources